330A voltage regulator made of three phase solid state relay with heatsink and fan cooling, 70KW proportional control. input 4-20mA or 1-5VDC or 2-10VDC, manual potentiometer adjustment: 2.2 - 4.7 K, output voltage range 0-380VAC

330A voltage regulator made of three phase solid state relay with heatsink and fan cooling, 70KW proportional control. input 4-20mA or 1-5VDC or 2-10VDC, manual potentiometer adjustment: 2.2 - 4.7 K, output voltage range 0-380VAC

When ordering, the user must state:

Load rating

1. Rated input voltage 2. Rated working current control mode selection: (optional below)

1. Manual potentiometer adjustment: 2.2 - 4.7 K

Automatic control model: 4-20 ma

Automatic control model: 1 - 5 VDC, 2 - 10 VDC

Product introduction

1. Multiple LED indicator lights on the panel display the working status and fault causes of the voltage regulator, which is convenient for timely maintenance in case of fault.

2. The PC board adopts SMD chip, with good anti-interference, low failure rate and no interference.

3. Slow start function is included to make the original more stable and durable when changing rapidly.

4. Proportional linear output, accurate temperature control, accuracy 0.3%, meet the requirements of various loads.

5. The whole machine is made of aluminum alloy, with small volume, good heat dissipation effect and 100% guiding fan for airflow heat dissipation.

6. Input mode: 4-20 mA, DC 1-5 V, DC 2-10 v. the three modes are freely switched and selected by p 1 jump without changing the host.

7. All series are equipped with high-speed fuse and overheat stop output protection switch to protect the power regulator.

8. Working conditions

Ambient temperature: - 20 ~ 65 ℃

Relative humidity: - 20-75% RH, no water condensation

Altitude: lower than 1000 meters, more than 1000 meters, according to GT / T 3859.1 - 2013 (5.3) standard derating use

9. The input power supply voltage at AC 1 and AC 2 terminals of PC board is AC 200 ~ 240 v.

10. There is no phase sequence relationship between the main power supply and the working voltage of PC board, so it is easy to use (automatic identification of 50 Hz ~ 60 Hz).

11. The air convection hole and cooling fan must be installed in the closed control box. If the heat dissipation is poor, please lower than 70%

Otherwise, the overheat protection function of the power controller will be started and the output will be stopped.

12. Please check whether the fan works normally from time to time. If not, you need to remove the fan fault before putting it into normal use.

Precautions before installation and use

Before installation, please check whether the model and specification of the voltage regulator are consistent with the order requirements. If not, please contact the supplier for replacement.

Before installation, please check whether the voltage regulator is damaged, the screw is loose, and the wiring falls off.

Load common line can not be connected to zero line or ground, otherwise SCR will be unable to turn off and lose control.

Please read the manual carefully before installation.

(this product is designed with ZL 20072 0128369.6 structure patent and 2.0082 e + 12 radiator patent.)

SEND INQUIRY NOW
CONTACT US
Phone: +86-13795385467 
WhatsApp: +86-13795385467
WeChat: GOLDRELAY
QQ: 3149075912
Send your inquiry

Item

Power( 380VAC)

Current of each phase

Module built in

heatsink

 

install( mm)

Dimension ( mm)

Fuse ( A)

Fuse type

Min load resistenc3e

CTH-I-30KW

30KW

52.4A

MTDX140A

E210

164*127

255*139*191

60

built in

14.4Ω

CTH-I-50KW

50KW

87.3A

MTDX220A

E250

204*127

295*139*191

100

built in

8.7Ω

CTH-I-70KW

70KW

122.3A

MTDX260A

E300

254*127

345*139*191

140

built in

6.2Ω

CTH-I-90KW

90KW

157.3A

MTDX320A

E350

304*127

395*139*191

175

built in

4.8Ω

CTH-I-110KW

110KW

192.2A

MTDX400A

E400

354*127

490*139*191

200

built out

3.9Ω

CTH-K-70KW

80KW

139.4A

MTDX260A

K300

250*200

345*210*210

140

built in

5.4Ω

CTH-K-90KW

100KW

174.2A

MTDX320A

K350

300*200

395*210*210

175

built in

4.3Ω

CTH-K-110KW
     (45℃)

120KW

209.1A

MTDX400A

K400

350*200

490*210*210

200

built in

3.6Ω

CTH-K-130KW
     (45℃)

130KW

227.1A

MTDX500A

K400

350*200

490*210*210

250

built in

3.3Ω

Note: the fuse for 110 kW and above power can not be installed in the controller due to the appearance and structure problem. It can be provided to the user for external use when installing (cth-k product is not listed).

Note: the above products are only applicable to electric heating load. The rated power and rated current can be selected as long as they are less than the rated value. The control mode is 4-20mA current regulation, 1-5vdc voltage regulation and 2-10vdc voltage regulation. The rated current in the table has included 15% overload design allowance.

The user should explain the control mode when purchasing, so as to adjust to the best state when leaving the factory。

IF YOU HAVE MORE QUESTIONS,WRITE TO US
Just tell us your requirements, we can do more than you can imagine.