ITEM

LOAD VOLTAGE

CURRENT

INDICATION

SAM6060A

24-660VAC

60A

LED IN AND OUT

SAM6080A

24-660VAC

80A

LED IN AND OUT

SAM60100A

24-660VAC

100A

LED IN AND OUT

SAM60120A

24-660VAC

120A

LED IN AND OUT

SAM60150A

24-660VAC

150A

LED IN AND OUT

SAM60200A

24-660VAC

200A

LED IN AND OUT

SAM60250A

24-660VAC

250A

LED IN AND OUT

SAM60300A

24-660VAC

300A

LED IN AND OUT

SAM80500A

40-800VAC

500A

LED OUT

SAM80600A

40-800VAC

600A

LED OUT

SAM80800A

40-800VAC

800A

LED OUT

SAM801200A

40-800VAC

1200A

LED OUT

SAM801600A

40-800VAC

1600A

LED OUT

 

SPECIFICATION

INPUT

CONTROL VOLTAGE

4-32VDC

90-280VAC

TURN OFF VOLTAGE

1VDC

15VAC

TURN ON VOLTAGE

4VDC

90VAC

CONTROL CURRENT

6-25mA(constant current circuit built in)

6-20mA

OUPUT

LOAD VOLTAGE

SAM40

SAM60

SAM80

24-530VAC

24-660VAC

40-800VAC

MIN TURN ON CURRENT

50mA

MAX TURN ON

1.5VAC

MAX TURN OFF

10mA

DU/DT

500V/us

MAX TURN ON-OFF TIME

RANDOM

1/2CIRCLE+1mA

ZERO CROSSING

10mA

DC CONTROL

40mA

MAX TURN OFF TIME

DC CONTROL

10mA

AC CONTROL

40mA

FREQUENCY

45-65HZ

OTHERS

MAX ISOLATE

INPUT AND OUTPUT 2000VAC

MIN INSULATION

BETWEEN INPUT AND OUTPUT WITH THE PLATE

INSULATION RESISTENCE

1000MΩ(500VDC)

WORKING TEMPERATURE

-40~80℃

 

DIMESION(mm)


Precautions for use
 1. Product manufacturers have made great efforts on product quality and reliability, but the semiconductor power devices used in solid state relay, such as improper selection or use, will still lead to irrecoverable damage. In addition, due to grid voltage fluctuation (usually
 A certain safety factor must be considered when selecting the type. For example: the long-term working current of electric heating should not exceed 60% of the current rated nominal value of SSR, and the working current of motor should not exceed 1 / 7 of the current rated nominal value of SSR.
 2. When the long-term working current is greater than or equal to 5A, the matching radiator must be installed, and the temperature of radiator bottom plate shall not exceed 80 ℃
 . If the ambient temperature is too high, air cooling must be adopted to accelerate the air flow in order to obtain better heat dissipation effect.
 3. In order to ensure that the solid-state relay is in close contact with the radiator surface during the installation process to achieve better heat dissipation effect, Our company is equipped with special heat-conducting film or special heat-conducting silicone grease according to different current levels. During installation, please place the heat-conducting film between the bottom plate of solid-state relay and the contact surface of radiator in parallel and fasten the installation fixing screw. For those equipped with heat-conducting silicone grease, please evenly apply appropriate amount of heat-conducting silicone grease on the bottom plate of solid-state relay and fasten the installation fixing screw.
 4. When the module is fastened to the radiator surface, M4 screw and spring washer are used to tighten the module with a torque of 4-6nm. After 3 hours of use, the module is tightened once with the same torque.
 5. In order to prevent the breakdown damage of solid-state relay caused by load short circuit or overload of current and voltage in use, it is strongly recommended to install and use the matching special fast fuse (our company can provide supporting services). For inductive load, a varistor should be installed at the solid-state output. Selection of varistor: 430-470v for 240V, 680-750v for 440V and 1100-1200v for 660V.
 6. When the solid state relay works, it must be ensured that there is enough voltage and current not exceeding the nominal trigger voltage and current value, such as the control terminal“
 4-32vdc ", that is, the minimum input voltage shall not be less than 4VDC, and the maximum input voltage shall not exceed 32vdc. Therefore, special attention should be paid to meet the triggering requirements of solid state relay in series or parallel operation.
7. The storage requirements of solid-state relay should be moisture-proof, moisture-proof, avoid rain, fall and violent fall. It should be stored in a ventilated, dry and non corrosive environment, and the humidity of the environment must be less than 80%.