UL certified SSR, GOLD SSR, 40A AC three phase SSR, AC control AC solid state relay, input 90-280VAC, input with LED indication, output three phase, oupt current capacity 40A, output voltage 40-530VAC

UL certified SSR, GOLD SSR, 40A AC three phase SSR, AC control AC solid state relay, input 90-280VAC, input with LED indication, output three phase, oupt current capacity 40A, output voltage 40-530VAC

The photoelectric isolation between the control loop and the load loop can be selected as zero crossing conduction or random conduction

International standard installation dimensions

Flame retardant engineering plastic shell is equipped with flame retardant transparent cover

LED indicates the working state

Built in RC absorption circuit, strong anti-interference ability, consistent three-phase / two-phase starting characteristics

It should be equipped with proper radiator and forced air cooling if necessary

4-32vdc or 90-280vac control

SEND INQUIRY NOW
CONTACT US
Phone: +86-13795385467 
WhatsApp: +86-13795385467
WeChat: GOLDRELAY
QQ: 3149075912
Send your inquiry

Product selection


ITEM

LOAD COLTAGE

LOAD CURRENT

INDICATION

SA2-4060D/A

40-530VAC

60A

TWO LED

SA2-4080D/A

40-530VAC

80A

TWO LED

SA2-40100D/A

40-530VAC

100A

TWO LED

SA2-40120D/A

40-530VAC

120A

TWO LED

 

ITEM

LOAD COLTAGE

LOAD CURRENT

INDICATION

SA3-4010D/A

40-480VAC

10A

INPUT LED

SA3-4015D/A

40-480VAC

15A

INPUT LED

SA3-4020D/A

40-480VAC

20A

INPUT LED

SA3-4025D/A

40-480VAC

25A

INPUT LED

SA3-4030D/A

40-480VAC

30A

INPUT LED

SA3-4040D/A

40-480VAC

40A

INPUT LED

SA3-4060D/A

40-480VAC

60A

INPUT LED

SA3-4080D/A

40-480VAC

80A

INPUT LED

SA3-40100D/A

40-480VAC

100A

INPUT LED

SA3-40120D/A

40-480VAC

100A

INPUT LED

Product parameters

input parameter

Control voltage

4-32VDC

90-280VAC

Turn-off

1VDC

15VAC

Turn-on

4VDC

90VAC

Control current

6-25mA
     (Built in constant current circuit)

6-20mA

output

Load voltage

SA3-40/SA2-40

SA3-66

40-480VAC

40-660VAC

Min turn-on

50mA

Max turn-on

1.7VAC

Max turn-off

10mA

Du/dt

500V/us

Max turn-on time

random

1/2circle+1mA

Zero crossing

10mA

AC control

40mA

Max turn-off
     current

DC control

10mA

AC control

40mA

 

45-65HZ

Other data

Min isolation

Input and output 2000VAC

Min insualtion

Input and output with the plate 2000VAC

Insulation resistence

1000MΩ(500VDC)


Dimension(mm)

 

Product wiring diagram

 

temperature curve

 

Precautions for use

1. Product manufacturers have made great efforts on product quality and reliability, but the semiconductor power devices used in solid state relay, such as improper selection or use, will still lead to irrecoverable damage. In addition, due to grid voltage fluctuation (usually
 A certain safety factor must be considered when selecting the type. For example: the long-term working current of electric heating should not exceed 60% of the current rated nominal value of SSR, and the working current of motor should not exceed 1 / 7 of the current rated nominal value of SSR.
 2. When the long-term working current is greater than or equal to 5A, the matching radiator must be installed, and the temperature of radiator bottom plate shall not exceed 80 ℃
 . If the ambient temperature is too high, air cooling must be adopted to accelerate the air flow in order to obtain better heat dissipation effect.
 3. In order to ensure that the solid-state relay is in close contact with the radiator surface during the installation process to achieve better heat dissipation effect, Our company is equipped with special heat-conducting film or special heat-conducting silicone grease according to different current levels. During installation, please place the heat-conducting film between the bottom plate of solid-state relay and the contact surface of radiator in parallel and fasten the installation fixing screw. For those equipped with heat-conducting silicone grease, please evenly apply appropriate amount of heat-conducting silicone grease on the bottom plate of solid-state relay and fasten the installation fixing screw.
 4. When the module is fastened to the radiator surface, M4 screw and spring washer are used to tighten the module with a torque of 4-6nm. After 3 hours of use, the module is tightened once with the same torque.
 5. The recommended tightening torque of M3 screw at control end is 0.8-1nm, and that of M5 screw at load end is 1.9-2.1nm.
 6. In order to prevent the breakdown damage of solid-state relay caused by load short circuit or overload of current and voltage in use, it is strongly recommended to install and use the matching special fast fuse (our company can provide supporting services). For inductive load, it is necessary to install varistor and RC absorption circuit at solid-state output end to prevent damage to thyristor in case of over-voltage. Selection of varistor (MOV): 430-470v for 240V, 680-750v for 40V and 1100-1200v for 660V.
 7. The storage requirements of solid-state relay should be moisture-proof, moisture-proof, avoid rain, fall and violent fall. Store in a well ventilated area
In dry, non corrosive gas environment, the humidity of the environment must be less than 80%.

 

IF YOU HAVE MORE QUESTIONS,WRITE TO US
Just tell us your requirements, we can do more than you can imagine.