·Ratings from 10A to 60A @ 12-280 VDC
·600 Volts transient overvoltage
·Removable IP 20 touch-safe cover
·Easy-to-use thermal pad
·Strengthened current design for heavy industrial loads
·Input LED status indicator
·CE approved, RoHS/EMC compliant.
PRODUCT SELECTION
Control Voltage | 10A | 20A | 40A | 60A |
3-15 VDC | SDP4010D | SDP4020D | SDP4040D | SDP4060D |
OUTPUT SPECIFICATIONS (1)
Description | 10A | 20A | 40A | 60A |
Operating Voltage [VDC] | 12-280 | 12-280 | 12-280 | 12-280 |
Transient Overvoltage [Vpk] | 600 | 600 | 600 | 600 |
Maximum Off-State Leakage Current @ Rated Voltage [μA] | 20 | 20 | 20 | 20 |
Maximum Load Current(2) [ADC] | 10 | 20 | 40 | 60 |
Minimum Load Current [mA] | 50 | 50 | 50 | 50 |
Maximum Surge Current In 5ms[Apk] | 40 | 80 | 160 | 240 |
Maximum On-State Voltage Drop @ Rated Current [VDC] | 2.5 | 2.5 | 2.5 | 2.5 |
Thermal Resistance Junction to Case (Rjc) [°C/W] | 0.4 | 0.36 | 0.23 | 0.15 |
Maximum On-State Resistance Per Switch (RDS-ON) [Ohms] | 0.015 | 0.012 | 0.008 | 0.006 |
Weight (typical) [Gram] | 132 | 132 | 132 | 132 |
INPUT SPECIFICATIONS (1) |
|
Description | SDP40xxD |
Control Voltage Range | 3-15 VDC |
Maximum Reverse Voltage | -15 |
Minimum Turn-On Voltage | 3.0 VDC |
Minimum Turn-Off Voltage | 1.0 VDC |
Minimum Input Current [mA] | 7 |
Maximum Input Current [mA] | 12 |
Nominal Input Impedance [Ohms] | 200 |
Maximum Turn-On Time [msec] | 3 |
Maximum Turn-Off Time [msec] | 3 |
GENERAL SPECIFICATIONS
Description | Parameters |
Dielectric Strength, Input/Output/Base (50/60Hz) | 2000 Vrms |
Minimum Insulation Resistance (@ 500 V DC) | 109 Ohm |
Maximum Capacitance, Input/Output | 8 pF |
Ambient Operating Temperature Range | -40 to 80°C |
Ambient Storage Temperature Range | -40 to 125 °C |
Housing Material | UL E211125: 94 V-0 |
Terminal Material | Gilded |
Baseplate Material | Aluminum (Except for 90A) |
Humidity | 85% non-condensing |
LED Input Status Indicator | Red |
RECOMMENDED MODEL & HEATSINK
Choosing compatible current is critical in selecting a right model of solid state relay. Our engineers recommend SSR models according to actual applications and internal components of relay. For example, when solid state relay is used for electric heating, because of the cold resistance effect (the resistance value is 60% of heating wire value when it is in cold state), the SSR’s current should be 1.67 times bigger than actual working current in order to prevent the over-current of solid state relay.
Therecommendations for the other types of application are provided in the similar reasons. Heatsink in the table are compatible (size and thermal parameters) with the corresponding SSRs.
Actual Load Current |
| 0.15A-5A | 0.15A-8A | 0.15A-15A | 0.15A-20A |
Recommended Model |
| SDP4010D | SDP4020D | SDP4040D | SDP4060D |
Recommended Heatsink | Panel | G60 | G60 | G80 | G100 |
Din Rail | CH60 | CH60 | CH80 | CH100 |
Application to DC Motors
Actual Load Current |
| 0.1A-0.75A | 0.1A-1.4A | 0.15A-2.5A | 0.15A-3A |
Recommended Model |
| SDP4010D | SDP4020D | SDP4040D | SDP4060D |
Recommended Heatsink | Panel | X50 | X50 | X50 | X50 |
Din Rail | CX50 | CX50 | CX50 | CX50 |
Application to Solenoid Valves
Actual Load Current |
| 0.1A-1.5A | 0.1A-2.8A | 0.15A-5A | 0.15A-6A |
Recommended Model |
| SDP4010D | SDP4020D | SDP4040D | SDP4060D |
Recommended Heatsink | Panel | X50 | X50 | G60 | G60 |
Din Rail | CX50 | CX50 | CH60 | CH60 |
GENERAL NOTES
(1)All parameters at 25°C and per section unless otherwise specified.
(2)Heat sinking required, for derating curves see next page.
Copyright © 2022 Jiangsu GOLD Electric Control Technology Co., Ltd. - www.goldssr.com All Rights Reserved.